歡迎來(lái)到匠仁醫療設備有限公司網(wǎng)站!

更多 > 新聞資訊
公司新聞
行業(yè)知識
檢測答疑
圖標 首頁(yè) >> 新聞資訊 > 檢測答疑

檢測答疑

內窺鏡設備維修:工業(yè)內窺鏡的使用方法

來(lái)源:http://www.arcanne-olergie.com/ 發(fā)布時(shí)間:2024-05-21 瀏覽量:0

  工業(yè)內窺鏡作為無(wú)損檢測儀器中的一種,很多人都不知道工業(yè)內窺鏡安裝操作與使用方法,接下來(lái)向大家介紹一下工業(yè)內窺鏡的使用方法。

As a type of non-destructive testing instrument, many people are unaware of the installation and usage methods of industrial endoscopes. Next, we will introduce the usage methods of industrial endoscopes.

  1.取出儀器:打開(kāi)儀器箱,取出主機。

1. Remove the instrument: Open the instrument box and remove the main unit.

  2.安裝電池:儀器箱內取出21700鋰電池,電池正極朝外裝入主機蓋好電池蓋。

2. Install the battery: Take out the 21700 lithium battery from the instrument box, with the positive pole facing outward, and install it into the main unit with the battery cover properly.

  3.安裝管線(xiàn):儀器箱內取出插入管裝入主機,取出過(guò)程中請握好探頭,避免跌落碰撞損壞探頭。

3. Pipeline installation: Take out the insertion tube from the instrument box and install it into the host. During the removal process, please hold the probe well to avoid falling and colliding to damage the probe.

  4.開(kāi)機準備:檢查設備各部分是否完好,確認TF卡已裝入,長(cháng)按電源鍵開(kāi)機。

4. Preparation for startup: Check if all parts of the device are intact, confirm that the TF card is installed, and press and hold the power button to start the device.

  5.功能校驗:檢查探頭照明是否正常工作,檢查儀器圖像顯示是否正常工作,擺動(dòng)搖桿檢查探頭轉向功能是否正常。

20200403031114827

5. Functional verification: Check if the probe lighting is working properly, check if the instrument image display is working properly, and swing the joystick to check if the probe steering function is normal.

  6.檢測操作:將內窺鏡管線(xiàn)伸入被測設備中,通過(guò)操作搖桿控制前端探頭的運動(dòng)方向。

6. Detection operation: Insert the endoscope pipeline into the tested equipment and control the movement direction of the front-end probe through the joystick.

  7.調節亮度:調節探頭照明光源的亮度,以獲得合適的亮度,使畫(huà)面達到清晰的效果。

7. Adjust brightness: Adjust the brightness of the probe lighting source to obtain the appropriate brightness and achieve the clearest effect on the image.

  8.拍照錄像:按下拍照/錄像鍵,對觀(guān)測結果進(jìn)行拍照或錄像。

8. Photo and video recording: Press the photo/video button to take a photo or video of the observation results.

  9.管線(xiàn)收回:操作搖桿回到中間位置,確認管線(xiàn)處于大致平直狀態(tài),然后將插入管緩慢取出,避免探頭跌落碰撞。

9. Pipeline retraction: Return the joystick to the middle position, confirm that the pipeline is roughly straight, and then slowly remove the insertion tube to avoid the probe falling and colliding.

  10.收納儀器:關(guān)閉電源開(kāi)關(guān),操作插入管與主機解鎖分離放入儀器箱中,關(guān)閉儀器箱上蓋,鎖好鎖扣。

10. Storage of instruments: Turn off the power switch, operate the insertion tube to unlock and separate from the host, and put it into the instrument box. Close the upper cover of the instrument box and lock the lock.

  以上就是有關(guān):內窺鏡設備維修 的介紹,想了解更多的內容請點(diǎn)擊:http://www.arcanne-olergie.com 我們將會(huì )全心全意為您提供滿(mǎn)分服務(wù),歡迎您的來(lái)電!

The above is an introduction to endoscopic equipment maintenance. To learn more, please click: http://www.arcanne-olergie.com We will wholeheartedly provide you with full score service. Welcome to call us!

s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫療設備有限公司
  • 匠仁醫療山東濟南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話(huà):13153199508
  • 地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室
  • 匠仁醫療湖南長(cháng)沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話(huà):13873135765
  • 地址:湖南省長(cháng)沙市雨花區勞動(dòng)東路820號恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室  湖南省長(cháng)沙市雨花區勞動(dòng)東路820號恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號